Supply and installation of thermal, cooling, acoustic, and fireproof insulation for commercial and industrial construction.

 

CLIMAVER®

CLIMAVER® system is a solution for manufacture of HVAC pipelines and bends of glass wool panels. The product is self-supporting HVAC pipeline for distribution of treated air for the purpose of heating, ventilation and air conditioning.

CLIMAVER® panel consists of an external surface layer, a core and an internal surface layer. The panel core is made of glass wool, thickness 25 or 40 mm. the external side of the panel is covered with aluminium film. The inside surface finish is represented either by another aluminium film or a resistant antibacterial fabric of glass fibre with high mechanical resistance. Both surface layers are reinforced with arming mesh of glass fibre.

The panels are used for manufacture of a straight air duct by straight line – bend method using special CLIMAVER® tools and accessories. Thanks to the manufacture of “pre-insulated” panels the pipeline assembly is quick and thus saves time and extra costs on site.

The CLIMAVER® system was designed to provide excellent thermal and acoustic properties and a high air-tightness level. These properties make the system energy-saving.

Manufacturing procedure for HVAC pipeline straight section production

CLIMAVER® Plus

Standard Solution for High Demand

The system panel CLIMAVER® Plus R and A2 Plus was designed to provide excellent acoustic and thermal properties and a high level of air-tightness. Thanks to these properties the system is energy-saving. The outside and the inside surface of the panel is covered with glass-fibre-reinforced aluminium film serving as vapour barrier.

The system CLIMAVER® Plus R, A2 Plus is an ideal solution for:

  • shopping centres,
  • office buildings,
  • educational facilities,
  • hospitals and poly-functional houses.
Quick installation

Quick installation

  • On-site assembly
  • Low weight
  • Easy tongue-and-groove connection
  • Auxiliary guide marks for formatting

Exceptional energy saving

Exceptional energy saving

  • Top class of air-tightness
  • Highly effective insulation properties

Noise absorption

Noise absorption

  • High sound transmission loss

Heat conductivity coefficient T [°C] 10 20 40 60 EN 12667
λ [W/(m·K)] 0,032 0,033 0,036 0,038
Flame reaction - - B-s1, d0 a A2-s1, d0 EN 13501-1
Sound absorption Hz 125 250 500 1000 2000 4000 EN ISO 354
EN ISO 11654
α - 0,20 0,20 0,20 0,60 0,50 0,40
200 × 200 dB/m 2,2 2,2 2,2 10,3 8 5,8
400 × 500 1,0 1,0 1,0 4,6 3,6 2,6
500 × 1000 0,7 0,7 0,7 3,1 2,4 1,8
αw - 0,3
Air-tightness - - Tightness class D EN 1507
Pressure resistance - Pa 800 EN 13403
Dimensional stability - % <1 EN 1604
Characteristics Symbol Size Unit Quantity and measured values Standard
3 000 1 190 25 24,99 299,88 2 399
Standard size/package information
Dimensions Thickness d [mm] m3/pack m3/pallet m3/truck
Length l [mm] Width b [mm]

CLIMAVER® Neto

Where silence is vital

The system panel CLIMAVER® Neto and A2 Neto was designed to provide excellent thermal performance and a high level of air-tightness, which makes the system energy-saving. The panel core is made of glass wool. The external surface is covered with aluminium film reinforced with glass fibre, serving as vapour barrier. The internal surface is provided with anti-bacterial fabric of glass fibre with high mechanical resistance.

The system CLIMAVER® Neto and A2 Neto is an ideal solution for spaces with high acoustic demand:

  • film theatres,
  • drama theatres,
  • educational facilities,
  • hospitals,
  • office buildings.
Noise absorption

Noise absorption

  • High sound transmission loss

Quick installation

Quick installation

  • On-site assembly
  • Low weight
  • Easy tongue-and-groove connection
  • Auxiliary guide marks for formatting

Exceptional energy saving

Exceptional energy saving

  • Top class of air-tightness
  • Highly effective insulation properties

Heat conductivity coefficient T [°C] 10 20 40 60 EN 12667
λ [W/(m·K)] 0,032 0,033 0,036 0,038
Flame reaction - - B-s1, d0 a A2-s1, d0 EN 13501-1
Sound absorption Hz 125 250 500 1000 2000 4000 EN ISO 354
EN ISO 11654
α - 0,35 0,65 0,75 0,85 0,90
0,90
200 × 200 dB/m 4,8 11,5 14,0 16,7 18,1
18,1
400 × 500 2,2 5,2 6,3 7,5
8,2 8,2
500 × 1000 1,5
3,5 4,2 5,0 5,4
5,4
αw - 0,85
Air-tightness - - Tightness class D EN 1507
Pressure resistance - Pa 800 EN 13403
Dimensional stability - % <1 EN 1604
Characteristics Symbol Size Unit Quantity and measured values Standard
3 000 1 190 25 24,99 299,88 2 399
Standard size/package information
Dimensions Thickness d [mm] m3/pack m2/pallet m2/truck
Length l [mm] Width b [mm]

CLIMAVER® Deco

Where design combines with comfort

The system panel CLIMAVER® A2 Deco was designed to provide excellent thermal performance and a high level of air-tightness. These properties make the system energy-saving. The panel core is made of glass wool, thickness 25 mm. The outer side of the panel is covered with colour fabric. The inside is protected with a resistant antibacterial fabric of glass fibre with high mechanical resistance.

Flame reaction class A2-s1, d0.

The CLIMAVER® A2 Deco system is ideal for spaces with visible interior distribution pipelines which are a decorative element of the interior:

  • restaurants,
  • cafés,
  • galleries,
  • cinemas,
  • theatres,
  • educational facilities,
  • administrativní budovy,
  • office and residential buildings.
3 000 1 210 40 18,15 199,70 1 597
Standard size/package information
Dimensions Thickness d [mm] m3/pack m3/pallet m3/truck
Length l [mm] Width b [mm]

CLIMAVER® Apta

For demanding environments

The system panel CLIMAVER® Apta, A2 and A1 was designed to provide excellent thermal performance and a high level of air-tightness, which makes the system energy-saving. The panel core is made of glass wool, thickness 40 mm. The outer side of the panel is covered with aluminium film reinforced with glass fibre, serving as vapour barrier. The inside is protected with a resistant antibacterial fabric of glass fibre.

Flame reaction class B-s1, d0, A2-s1, d0 and A1.

The system CLIMAVER® Apta, A2 and A1 Apta is an ideal solution for spaces with high acoustic and thermal-technical property demand.

3 000 1 190 25 24,99 299,88 2 399
Standard size/package information
Dimensions Thickness d [mm] m3/pack m3/pallet m3/truck
Length l [mm] Width b [mm]

Energy Saving

Pressure loss

The inside the air duct of CLIMAVER® brand is identical in surface roughness with HVAC pipeline of galvanised sheet metal.

Tests of pressure loss in straight and spatially and directionally complex pipeline of CLIMAVER® panels show identical results. That means that use of this system is able to reduce pressure loss by friction by up to 40 % with regard to the remaining part of the pipeline (subject to the air duct geometry and air flow rate).

Dimensions of and pressure loss in air ducts of CLIMAVER® panels are calculated by the calculation program ClimCalc Dimension.

Results of tests for air leak factor and tightness class pursuant to EN 13403

CLIMAVER® system assures ten-fold better air tightness (tightness class D) than standard sheet metal pipeline (tightness class B) pursuant to EN 12237 standard for metal pipeline and EN 13403 for non-metal pipeline.

The test results for air leak factor and for tightness class comply with EN 13403.

[:en]Pressure loss informative calculations[:]

Life in silence

Acoustic Properties

Air duct CLIMAVER® Neto combines excellent sound absorption with mechanical resistance. The sound transmission loss coefficient α is defined by the ratio of energy absorbed by a surface area to the energy hitting the same area.
The more the coefficient approaches 1, the higher the sound absorption. The CLIMAVER® Neto Neto series guarantees weighed sound absorption coefficient value of 0.85.

[:de]Schallabsorption (αw)[:ru]Поглощаемость звука (αw)[:]
[:en]Sound absorbtion (α<sub>w</sub>)[:de]Schallabsorption (αw)[:ru]Поглощаемость звука (α<sub>w</sub>)[:]
Sound absorption coefficient (α) 125 Hz 250 Hz 500 Hz 1 kHz 2 kHz αw
0,35 0,65 0,75 0,85 0,90 0,85

The following formula is used for calculation of approximate sound transmission loss from the sound absorption coefficients (α) obtained by acoustic tests.

ΔL = 1.05 x α1.4 × P / S, where: α is sound absorption coefficient, P is inner perimeter of cross section (m), S is inner diameter of pipeline (m2).

Pipeline sound transmition loss for CLIMAVER® Neto (dB/5 m/400 × 200 mm)

Metal pipeline 2 2 7,5 7,5 3
CLIMAVER® Plus 8,5 8,5 8,5 38,5 30
CLIMAVER® Neto 18 43 52,5 62,54 68
CLIMAVER® Apta 22 43 53 68 38
Product Frequency (Hz)
125 250 500 1000 2000

In addition to equipment noise absorption, CLIMAVER® Neto further eliminates noise resulting from vibrations of the pipeline itself, as in case of galvanised sheet metal pipelines.

CLIMAVER® Certification

Safety first

The manufacturer of the ISOVER insulation material cares for human health and environment protection.

ISOVER is member of the Czech Council for Low-Energy Buildings and is certified according to ISO 9001 standard.

CLIMAVER® holds certificates pursuant to EN 14303 and EN 13403 standards.
Production of CLIMAVER® panels is based on recycled glass in up to 80 %.

Effects of glass wool fibre on humans have been profoundly tested by independent medical experts and research teams. The International Agency for Research on Cancer (IARC), member of the World Health Organisation (WHO), classified in EU 97/69/EC directive glass wool fibre as non-carcinogenic, is they are bio-degradable. CLIMAVER® meets test criteria of the European Certification Board for mineral wool products (EUCEB).

[:cs]CLIMAVER<sup>®</sup> Plus R[:]

Flame reaction

CLIMAVER® products are classified according to flame reaction as follows:

A2-s1, d0 CLIMAVER® A2 PLUS
B-s1, d0 CLIMAVER® PLUS R
B-s1, d0 CLIMAVER® NETO
A2-s1, d0 CLIMAVER® A2 NETO
A2-s1, d0 CLIMAVER® A2 DECO

EUROCLASS is a harmonised European classification system according to which products are classified according to their flame reaction as A1, A2, B, C, D, E and F. Additional criteria are marked with “s” and “d”. These provide information about smoke development progress (while s1 means no smoke, s3 means smoke with high combustible emission levels) and potential burning drop fall (d0 none, d3 maximum).

A1 Does not contribute to fire None (no burning drops and particles)
A2-s1, d0 Does not substantially contribute to fire spread None (no burning drops and particles)
B-s1, d0 Very limited contribution to fire spread Smoke, burning drop and particle generation
C Limited contribution to ignition Smoke, burning drop and particle generation
D Contributes to ignition Smoke, burning drop and particle generation
E Significant contribution to ignition Smoke, burning drop and particle generation (considerable smoke expected)
F Non-meeting of criteria of class E
Class Flame reaction Further testing criteria

Guaranted air quality and maintenance

Pipeline cleaning

CLIMAVER® air ducts are specially designed to assure their effective cleaning. The continuous inside layer is resistant to mechanical brushing and cleaning with compressed air.

AELSA (Spanish Association of Companies for Air Duct Cleaning) certifies that CLIMAVER® ducts can be perfectly cleaned with preserved integrity. This means that no further protection of the air duct inside is needed. Thanks to that CLIMAVER® maintains its original parameters.

[:cs]CLIMAVER<sup>®</sup> A2 Neto[:]

CLIMAVER® was tested pursuant to EN ISO 16000-10:2006 and meets low-emission requirements for buildings.

CLIMAVER® is an ideal system for effective fresh air distribution inside buildings. CLIMAVER® air ducts have been successfully tested for antifungal and antibacterial protection in compliance with European standard EN 13403.

Climaver® Plus
Climaver® Neto
Climaver® Deco
CLIMAVER® Apta